IEEE Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission Lines(PDF COPY)


The IEEE Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission Lines, known as IEEE C37.106, provides guidelines for the application, testing, and maintenance of automatic reclosing devices used in power systems. Here's an overview of key aspects covered in the guide:

  1. Purpose and Scope:

    • The guide aims to enhance the reliability of power systems by providing recommendations for the application of automatic reclosing on AC distribution and transmission lines.
  2. Automatic Reclosing Basics:

    • Defines automatic reclosing as the process of closing a circuit breaker after it has opened due to a fault, with the goal of restoring power quickly if the fault is transient or temporary.
  3. Application Considerations:

    • Provides guidance on when to apply automatic reclosing based on factors such as system characteristics, fault types, and protection coordination.
    • Considers factors like fault clearing times, system voltage, and the impact on customer service reliability.
  4. Reclosing Sequence:

    • Describes the sequence of automatic reclosing, including the number of reclosing attempts and the time delay between attempts.
    • Emphasizes coordination with other protective devices to avoid unnecessary reclosing and enhance system stability.
  5. Testing and Maintenance:

    • Outlines procedures for testing automatic reclosing devices during commissioning and regular maintenance.
    • Recommends testing not only the reclosing devices but also associated protection and control systems.
  6. Communication and Coordination:

    • Highlights the importance of communication between protective devices and coordination with other protection schemes to optimize system reliability.
    • Discusses considerations for communication channels and protocols.
  7. Monitoring and Recording:

    • Recommends the installation of monitoring devices to record information related to automatic reclosing events.
    • Emphasizes the analysis of recorded data to assess the performance of the reclosing system and identify any issues.
  8. Special Considerations:

    • Addresses specific scenarios or conditions that may require special considerations in the application of automatic reclosing.
    • Examples include capacitor switching, system grounding, and reclosing after a fault on a neighboring circuit.
  9. Documentation:

    • Stresses the importance of maintaining comprehensive documentation related to the application, testing, and maintenance of automatic reclosing devices.

Users should refer to the latest version of the IEEE C37.106 guide for detailed and specific information. Implementing the recommendations in this guide helps utilities and system operators enhance the reliability and efficiency of their power systems through the effective use of automatic reclosing devices.