Relay Setting Calculation For Generator Relay Panels (PDF COPY)


Setting relay parameters for generator protection involves considering various factors to ensure reliable and selective operation. Here's a brief overview:

  1. Overcurrent Protection:

    • Determine the generator's full load current and calculate the pickup and time delay settings based on expected inrush and fault currents.
    • Coordination with downstream devices is crucial to avoid unnecessary tripping.
  2. Voltage Protection:

    • Set overvoltage and undervoltage relays to safeguard the generator against voltage anomalies.
    • Consider nominal voltage, acceptable voltage limits, and time-delay settings.
  3. Frequency Protection:

    • Establish settings for overfrequency and underfrequency relays based on the generator's nominal frequency and acceptable operating limits.
  4. Rotor Earth Fault Protection:

    • Implement protection against rotor earth faults with proper settings to detect and clear faults without unnecessary trips.
  5. Loss of Excitation Protection:

    • Set parameters to detect loss of excitation, ensuring the generator remains connected to the grid during normal operation.
  6. Reverse Power Protection:

    • Protect the generator from reverse power situations by configuring relay settings based on the maximum allowable reverse power.
  7. Thermal Overload Protection:

    • Consider the generator's thermal capacity and establish settings for thermal overload protection, preventing overheating.
  8. Coordination with Other Relays:

    • Ensure coordination between generator protection relays and those of adjacent equipment to maintain system reliability and selectivity.
  9. Testing and Simulation:

    • Conduct testing and simulation studies to validate the relay settings and assess their performance under different operating conditions.
  10. Standards and Guidelines:

    • Adhere to relevant standards such as IEEE or IEC for generator protection and consult manufacturer recommendations for specific relay models.
  11. Documentation:

    • Document all relay settings, including pickup values, time delays, and coordination parameters, for future reference and maintenance.

Relay setting calculations require a thorough understanding of the generator, the surrounding power system, and the specific relay characteristics. Collaboration with experienced electrical engineers and adherence to industry standards are essential for a reliable protection scheme.