Cable diagnostic in MV underground cable networks


Cable diagnostic techniques play a crucial role in assessing the condition and health of medium voltage (MV) underground cable networks. These diagnostic methods help utilities and operators identify potential faults, degradation, and insulation weaknesses in cables, allowing for proactive maintenance and ensuring reliable operation. Here are some common cable diagnostic techniques used in MV underground cable networks:

1. Partial Discharge (PD) Measurement:

  • PD measurement is a non-destructive diagnostic technique used to detect and localize partial discharge activity within cable insulation.
  • PD signals indicate the presence of localized insulation defects, voids, or degradation, which can lead to insulation breakdown and cable failure.
  • PD measurements are typically performed using specialized sensors and monitoring equipment installed at cable terminations or joints.

2. Tan Delta and Capacitance Measurement:

  • Tan delta measurement assesses the dielectric losses and power factor of cable insulation, providing information about its condition and moisture content.
  • Capacitance measurement determines the capacitance value of the cable, which can indicate changes in insulation geometry or moisture ingress.
  • These measurements are conducted using portable test equipment connected to cable terminations or joints.

3. Time Domain Reflectometry (TDR):

  • TDR is a diagnostic technique used to locate cable faults such as breaks, discontinuities, or impedance changes.
  • By sending short pulses of electromagnetic waves along the cable and analyzing the reflected signals, TDR can accurately pinpoint the distance to the fault location.
  • TDR measurements are typically performed using handheld or portable TDR instruments.

4. Dissipation Factor (DF) and Power Factor (PF) Measurement:

  • DF and PF measurement assess the dielectric losses and insulation quality of cable systems.
  • High DF or PF values may indicate insulation degradation, moisture ingress, or contamination, warranting further investigation or maintenance.
  • These measurements are typically performed using specialized test equipment and sensors connected to cable terminations or joints.

5. Insulation Resistance Measurement:

  • Insulation resistance measurement assesses the insulation resistance between cable conductors and between conductors and ground.
  • A decrease in insulation resistance may indicate insulation degradation, moisture ingress, or insulation aging.
  • Insulation resistance tests are conducted using megohmmeters or insulation resistance testers.

6. Thermal Imaging:

  • Thermal imaging is used to identify hot spots or temperature anomalies along cable routes, which may indicate loose connections, overloaded circuits, or insulation defects.
  • Thermal cameras are employed to capture infrared images of cable terminations, joints, and sections of the cable route.

7. Acoustic and Ultrasonic Detection:

  • Acoustic and ultrasonic detection techniques are used to locate partial discharge activity, corona discharge, or insulation breakdown by detecting emitted acoustic or ultrasonic waves.
  • Handheld or portable detection devices are used to scan cable terminations, joints, and cable routes.

By employing these cable diagnostic techniques, operators and utilities can assess the condition of MV underground cable networks, identify potential issues, and prioritize maintenance and repair activities to ensure the reliability and longevity of the cable infrastructure.